A Nice motorised gate that refuses to open should never leave you stranded. Every model has a manual release, and most faults can be diagnosed on the control board.
Switching the gate to manual
- Insert the release key supplied (triangular or cylindrical depending on the model) into the motor housing.
- Turn as shown on the cover, then pull the release lever: the carriage or rack is freed.
- Move the gate by hand, without forcing, to the desired position.
- To re-engage, put the lever back and send a command: the motor re-synchronises.
Checking a Robus or Road board after a fault
- Fuses: visually inspect the mains fuse and the low-voltage accessory fuse (broken filament); always replace with the same rating.
- Wiring: check the tightness of the power, aerial and photocell terminals – a loose wire is the most common fault after a storm.
- Diagnostic LED: the flashing sequence identifies the error (blocked photocells, motor overload, encoder); count the flashes and check the manual.
Safety first: cut the power before opening the box, and never touch the capacitors. If a fuse keeps blowing, the board or motor is faulty: our technicians repair Nice and all other gate motorisations throughout Île-de-France.